同时本文对锑工艺区别于其他N型注入工艺监测的原因做了进一步分析
原来的锑注入监测工艺周期时间长成本高,本文提出了一种改进的监测方法,通过低温快速热退火实现了短周期,剂量敏感的且具有良好重复性
作为N型掺杂的锑注入其工艺稳定性直接影响了外延层的位错/层错缺陷
该产品生产中采用了埋层注入和外延工艺[1]
( 1、 上海华虹NEC电子有限公司
CHENG Xiu-lan 2, ( 1、 Shanghai Hua Hong NEC Electronics Company, Limited
2、 上海交通大学微电子学院
) Abstract: With more application field of large size LCD panel in recent years, high voltage LCD driver is focused, which may need buried layer implant and EPI process
The old monitoring method in antimony implant need long period and high cost, in this paper we advise a improved monitoring method by rapid thermal annealing at low temperature, which give us short test period, high dose sensitivity and good repeatability
Also some cause analysis is given based on the difference between antimony and other N type dopant process monitoring
Keywords: antimony; implantation; rapid thermal annealing; low temperature; sheet resistance 下载PDF阅读器 PDF全文下载: 初稿 ( 110 ) 作者简介: 通信联系人: 【收录情况】 中国科技论文在线: 郑刚